Displaying report 1-1 of 1.
Reports until 13:13, Friday 09 March 2018
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 13:13, Friday 09 March 2018 (40930)
offload of raw minute trends from h1tw1 started

WP7399

The process of offloading raw minute trend files from h1tw0 to the DAQ SATABOYS has been started. The first part of the procedure was to switch writing the current data to a new directory on h1tw1 and adding the directory which contains the last 6 months of data to the NDS archive_raw_minute_dirs list. This was done and both NDS were restarted at noon.

The next step is to use h1fw1 to copy of files from h1tw1's SSD RAID over to the SATABOY RAID (a fully compressed ZFS specifically built to hold archived raw minute). I started this process at 12:52 PST. Note that this transfer uses ionice to reduce this transfer's impact on the frame writing.