I have a script check_guardian_nodes_against_medm_screen which reports: nodes which exist but are not on MEDM screen, nodes which are on MEDM screen which do not exist. It produced one report: CS_BRS on the overview but does not exist. I have removed this node from the MEDM file.
Note: INJ_TRANS is white on the overview, Jamie is working on restarting this node.
The INJ_TRANS node can not be started, for unknown reasons. However, the h1guardian0 host is apparently suffering from some sort of NFS lockup having to do with the injection machine, which presumably explains what we're seeing. Dave is on the case. Once this issue is resolved, the INJ_TRANS node should be able to be restarted with the following commands: