The bias slider values that were stored in the SDF SAFE file were old. When there was a boot fest last Thur of ETMY SUS (alog 40913), these values got restored and the ETMY no longer pointed to ~0 on the Oplev. Today I trended those values an dataviewer in order to restore them. The latest values which we mechanically pointed the ETMY to, used a little bit of bias:
PIT 34.4
YAW -105.0
However these values don't put it on the Oplev in PIT now. Today it wants bias slider values below in order to be well centered on the OL:
PIT -135.6
YAW -105.0
Whatever. So many mysteries, so little time. Door closed.
I have loaded these newest bias values into the ETMY SUS SDF SAFE file.