Displaying report 1-1 of 1.
Reports until 13:30, Tuesday 13 March 2018
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 13:30, Tuesday 13 March 2018 - last comment - 16:24, Tuesday 13 March 2018(40993)
CDS maintenace summary

WP7410 susopo

Jeff K, Dave:

A new h1susopo model was installed sans DACKILL in the OFI part.

Beckhoff Code Change

Daniel, Dave:

A new h1ecatc1plc4 was installed. New INI file was added to the DAQ. New autoBurt.req file added to target. New monitor.req added to SDF. I restarted h1sysecatc1plc4sdf on h1build. I accepted and monitored all the new channels in the safe.snap file.

WP7399 h1tw1 offload

Dave:

I have completed the first part of h1tw1's raw minute trend files offload. The files have been copied and verified from h1tw1 to h1fw1 (served by h1nds1). The files have been deleted from h1tw1, reducing its /trend RAID disk usage from 96% to 10%. The final part of the process is to copy the files from "h1fw1's SATABOY" to "h1tw0's SATABOY" so that h1nds0 can see the files. There is no rush to do this since h1nds1 is the default nds.

DAQ Restart

We only needed one DAQ restart, performed at 12:05 PDT, which:

using new h1susopo ini

using new h1ecatc1plc4 ini

restarted h1nds1 with new daqdrc (gets past 6 months of minute trends from SATABOY)

restarted h1nds0 with new daqrc (no longer has past 6 months of minute trends from h1tw1)

restart log is attached.

 

Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 16:24, Tuesday 13 March 2018 (40998)SQZ, SUS
The above mentioned h1susopo model restart closes WP 7410
Displaying report 1-1 of 1.