Nutsinee Terry Daniel
OPO locking:
Fibers:
Translation stage:
Next:
Taking the 62% dip in reflection at face value, we can calculate the crystal loss assuming we know the input coupler (nominally 98% reflectivity) and neglecting any effects from mode mismatch:
| R input coupler | Crystal Loss | Finesse | Power buildup | Crystal Loss | Finesse | Power buildup |
| 0.975 | 0.60% | 200 | 103 | 10% | 48 | 6.1 |
| 0.980 | 0.48% | 250 | 129 | 8.2% | 59 | 7.5 |
| 0.985 | 0.36% | 335 | 173 | 6.2% | 79 | 10 |
There are two possible solutions. However, the high loss solution is not very likely.