jim.warner@LIGO.ORG - posted 15:59, Monday 19 March 2018 (41067)
PSL weekly status


Laser Status:
SysStat is good
Front End Power is -0.003262W (should be around 30 W)
HPO Output Power is -0.04724W
Front End Watch is RED
HPO Watch is RED

PMC:
It has been locked 0 days, 0 hr 0 minutes (should be days/weeks)
Reflected power = 0.008512Watts
Transmitted power = -0.02508Watts
PowerSum = -0.01657Watts.

FSS:
It has been locked for 0 days 0 hr and 0 min (should be days/weeks)
TPD[V] = 0.06625V (min 0.9V)

ISS:
The diffracted power is around 3.3% (should be 3-5%)
Last saturation event was 14 days 2 hours and 58 minutes ago (should be days/weeks)

Possible Issues:
Front End Power is Low
FSS TPD is low
LRA out of range, see SYSSTAT.adl
 