TCSX QPD glitches from new DQ channels

I've looked at 3 consecutive glitches in TCSX QPD B using the _DQ channels added yesterday.  The shape of all 3 glitches are the same, and have a shape that looks very much like a step function (with a second glitch about 3/4 of the way through the first).  To the best that I can measure in dtt, the interval between the first and second glitch is 900.098 seconds, and between the second and third glitch is 900.577 seconds, so 15 minutes +/-0.5 seconds.  Attached plots of the three glitches show that the ISS and RIN signals also see the glitch.  Related alog 41076.

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 12:16, Friday 23 March 2018 (41126)

plot showing one hour of data, showing the qpds in H1 and L1  glitch every 15 minutes: 

Images attached to this comment