Displaying report 1-1 of 1.
Reports until 17:24, Friday 30 March 2018
LHO VE
chandra.romel@LIGO.ORG - posted 17:24, Friday 30 March 2018 - last comment - 21:06, Saturday 31 March 2018(41234)
Pumping XBM & new PT-170 gauge

Starting pumping the XBM today. QDP80 is currently valved out with pressure at 45 Torr. Will resume on Monday. Blow down measured -15degC dew point.

Before pump down I replaced PT-170 full range gauge on BSC7 with a brand new gauge. PT-170 and PT-180 have been acting strange, and after some conversations with manufacturer, we agreed to send at least one unit back for contamination analysis.

Comments related to this report
kyle.ryan@LIGO.ORG - 13:45, Saturday 31 March 2018 (41237)
1345 hrs. local, Saturday 

PT170 showing XBM vented.  New gauge?  
chandra.romel@LIGO.ORG - 21:06, Saturday 31 March 2018 (41238)

Chandra on site 7:30 pm to 9 pm local

I came on site to check this out. I found that the new IP6 valve flange to beam tube was improperly torqued with a large leak to XBM volume. I also found the gate valve not fully closed (not cammed over).

Reconnected purge air to XBM and slightly opened IP6 gate valve to allow flow path for flushing to dry out the volume. We'll check the blow down dew point on Monday.

Displaying report 1-1 of 1.