Between ETMY closeout work at EY, Travis and I continue to rebuild the ETMX suspension at EY.
We're working towards installation of the new AERM07 mass into the reaction chain. Last week we removed the ERM02 mass from the lower structure frame. Yesterday we gutted the PenRe mass at the stage above this mass to rebuild it with heavier cans which compensate for the lighter AERM with the hole in the middle. The 2 lowest masses of this reaction chain need to maintain their total before-rebuild weight, so the PenRe will need to be built to 64,303g:
| OLD Weights (g) | NEW Weights (g) | |
| PenRe Mass | 53,183* | 64,303 |
| ERM02/AERM07 Mass | 26,055* | 14,935* |
| Total PenRe+A/ERM | 79,238 | 79,238 |
* Weighed with scale during this rebuild
For my record keeping:
| OLD PenRe | NEW PenRe | |
| Parts in Body of mass | 21,023* | 32,143 |
| Body | 32,160* | 32,160* |
| Total PenRe | 53,183* | 64,303 |