New h1psliss model for production ISS outer-loop chassis
Keita, Ben, Dave, Richard, Fil:
I installed a new h1psliss model which supports the production ISS outer-loop chassis. Main changes are: no need to borrow ADC channels from FSS, no need to borrow DAC channels from PMC, PD[1-80]_DC channels removed, EXC output removed (instead excitation is summed with TXY output channel digitally).
Model and DAQ were restarted at 13:30. The restart delay was due to unknown compile problems encountered when trying to disconnect the EXC output channel from the ISS part. Because this is a common part, I put in a work-around which did not change the number of output ports.
The new ADC channel layout is defined in the wiki https://cdswiki.ligo-wa.caltech.edu/wiki/H1PSLISSModelAdcDacChannels
New Beckhoff code
Daniel, Patrick, Dave:
New DAQ chan lists for ecatc1plc[2,3,4] were installed this morning. Chiller work changed PLC2,3 and SQZ work changed PLC4.
Some SDF updates are outstanding.
ecatc1plc4:
new SDF monitor list installed (h1sysecatc1plc4sdf restarted)
new channels in SDF have been accepted and monitored in snap file
new autoBurt.req file installed