subset of guardian nodes moved to h1guardian1 for further evaluation

I have moved a subset of guardian nodes to the new configuration on h1guardian1.  This is to try to catch more of the segfaults we were seeing during the last upgrade attempt, that we have not been able to reproduce in testing.

The nodes should function normally on the new system, but given  what we saw before we expect to see segfaults with a mean time to failure of about 100 hours.  I will be baby sitting the nodes on the new setup, and will restart them as soon as they crash.

The nodes that have been moved to the new system are all the SUS and SEI nodes in the input chambers, BS, and the arms.  No nodes from HAM4, HAM5, or HAM6 were moved.  Full list of nodes now running on h1guardian1:

jameson.rollins@opsws12:~ 0$ ssh guardian@h1guardian1 list
HPI_BS
HPI_ETMX
HPI_ETMY
HPI_HAM1
HPI_HAM2
HPI_HAM3
HPI_ITMX
HPI_ITMY
ISI_BS_ST1
ISI_BS_ST1_BLND
ISI_BS_ST1_SC
ISI_BS_ST2
ISI_BS_ST2_BLND
ISI_BS_ST2_SC
ISI_ETMX_ST1
ISI_ETMX_ST1_BLND
ISI_ETMX_ST1_SC
ISI_ETMX_ST2
ISI_ETMX_ST2_BLND
ISI_ETMX_ST2_SC
ISI_ETMY_ST1
ISI_ETMY_ST1_BLND
ISI_ETMY_ST1_SC
ISI_ETMY_ST2
ISI_ETMY_ST2_BLND
ISI_ETMY_ST2_SC
ISI_HAM2
ISI_HAM2_SC
ISI_HAM3
ISI_HAM3_SC
ISI_ITMX_ST1
ISI_ITMX_ST1_BLND
ISI_ITMX_ST1_SC
ISI_ITMX_ST2
ISI_ITMX_ST2_BLND
ISI_ITMX_ST2_SC
ISI_ITMY_ST1
ISI_ITMY_ST1_BLND
ISI_ITMY_ST1_SC
ISI_ITMY_ST2
ISI_ITMY_ST2_BLND
ISI_ITMY_ST2_SC
SEI_BS
SEI_ETMX
SEI_ETMY
SEI_HAM2
SEI_HAM3
SEI_ITMX
SEI_ITMY
SUS_BS
SUS_ETMX
SUS_ETMY
SUS_IM1
SUS_IM2
SUS_IM3
SUS_IM4
SUS_ITMX
SUS_ITMY
SUS_MC1
SUS_MC2
SUS_MC3
SUS_PR2
SUS_PR3
SUS_PRM
SUS_RM1
SUS_RM2
SUS_TMSX
SUS_TMSY
jameson.rollins@opsws12:~ 0$

guardctrl for nodes on h1guardian1

NOTE: Until the new system has been put fully into production, "guardctrl" interaction with these nodes on h1guardian1 is a bit different.  To start/stop the nodes, or get status or view the logs, you will need to send the appropriate guardctrl command to guardian@h1guardian1 over ssh, e.g.:

jameson.rollins@opsws12:~ 0$ ssh guardian@h1guardian1 status SUS_BS
● guardian@SUS_BS.service - Advanced LIGO Guardian service: SUS_BS
   Loaded: loaded (/usr/lib/systemd/user/guardian@.service; enabled; vendor preset: enabled)
  Drop-In: /home/guardian/.config/systemd/user/guardian@.service.d
           └─timeout.conf
   Active: active (running) since Sun 2018-04-08 14:48:47 PDT; 1h 53min ago
 Main PID: 24724 (guardian SUS_BS)
   CGroup: /user.slice/user-1010.slice/user@1010.service/guardian.slice/guardian@SUS_BS.service
           ├─24724 guardian SUS_BS /opt/rtcds/userapps/release/sus/common/guardian/SUS_BS.py
           └─24745 guardian-worker SUS_BS /opt/rtcds/userapps/release/sus/common/guardian/SUS_BS.py

Apr 08 14:48:50 h1guardian1 guardian[24724]: SUS_BS executing state: ALIGNED (100)
Apr 08 14:48:50 h1guardian1 guardian[24724]: SUS_BS [ALIGNED.enter]
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS REQUEST: ALIGNED
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS calculating path: ALIGNED->ALIGNED
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS same state request redirect
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS REDIRECT requested, timeout in 1.000 seconds
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS REDIRECT caught
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS [ALIGNED.redirect]
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS executing state: ALIGNED (100)
Apr 08 16:01:45 h1guardian1 guardian[24724]: SUS_BS [ALIGNED.enter]
jameson.rollins@opsws12:~ 0$

Problems encountered during move

A couple of the SEI systems did not come back up to the same states they were in before the move.  This caused a trip on ETMY HPI, and ETMX ISI_ST1.  I eventually recovered everything back to the states they were in at the beginning of the day.

The main problem I've been having is with the ISI_*_SC nodes.  They all are supposed to be in the SC_OFF state, but a couple of the nodes are cycling between TURNING_OFF_SC and SC_OFF.   For instance, ISI_ITMY_ST2_SC is showing the following:

2018-04-09_00:00:39.728236Z ISI_ITMY_ST2_SC new target: SC_OFF
2018-04-09_00:00:39.729272Z ISI_ITMY_ST2_SC executing state: TURNING_OFF_SC (-14)
2018-04-09_00:00:39.729667Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.enter]
2018-04-09_00:00:39.730468Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.main] timer['ramping gains'] = 5
2018-04-09_00:00:39.790070Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.run] USERMSG 0: Waiting for gains to ramp
2018-04-09_00:00:44.730863Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.run] timer['ramping gains'] done
2018-04-09_00:00:44.863962Z ISI_ITMY_ST2_SC EDGE: TURNING_OFF_SC->SC_OFF
2018-04-09_00:00:44.864457Z ISI_ITMY_ST2_SC calculating path: SC_OFF->SC_OFF
2018-04-09_00:00:44.865347Z ISI_ITMY_ST2_SC executing state: SC_OFF (10)
2018-04-09_00:00:44.865730Z ISI_ITMY_ST2_SC [SC_OFF.enter]
2018-04-09_00:00:44.866689Z ISI_ITMY_ST2_SC [SC_OFF.main] SENSCOR_Y_IIRHP FMs:[4] is not in the correct configuration
2018-04-09_00:00:44.866988Z ISI_ITMY_ST2_SC [SC_OFF.main] USERMSG 0: SENSCOR_Y_IIRHP FMs:[4] is not in the correct configuration
2018-04-09_00:00:44.927099Z ISI_ITMY_ST2_SC JUMP target: TURNING_OFF_SC
2018-04-09_00:00:44.927619Z ISI_ITMY_ST2_SC [SC_OFF.exit]
2018-04-09_00:00:44.989053Z ISI_ITMY_ST2_SC JUMP: SC_OFF->TURNING_OFF_SC
2018-04-09_00:00:44.989577Z ISI_ITMY_ST2_SC calculating path: TURNING_OFF_SC->SC_OFF
2018-04-09_00:00:44.989968Z ISI_ITMY_ST2_SC new target: SC_OFF
2018-04-09_00:00:44.991117Z ISI_ITMY_ST2_SC executing state: TURNING_OFF_SC (-14)
2018-04-09_00:00:44.991513Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.enter]
2018-04-09_00:00:44.993546Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.main] timer['ramping gains'] = 5
2018-04-09_00:00:45.053773Z ISI_ITMY_ST2_SC [TURNING_OFF_SC.run] USERMSG 0: Waiting for gains to ramp

Note that the problem seems to be that it's failing a check for the SENSCOR filter banks being in the correct state once SC_OFF has been achieved.  Here are the nodes that are having problems, and the messages they're throwing:

ISI_HAM2_SC     [SC_OFF.main] SENSCOR_GND_STS_Y_FIR FMs:[1] is not in the correct configuration
ISI_HAM3_SC     [SC_OFF.main] SENSCOR_GND_STS_Y_FIR FMs:[1] is not in the correct configuration
ISI_BS_ST2_SC   [SC_OFF.main] SENSCOR_Y_IIRHP FMs:[4] is not in the correct configuration
ISI_BS_ST1_SC   [SC_OFF.main] SENSCOR_GND_STS_Y_WNR FMs:[6] is not in the correct configuration
ISI_ITMX_ST2_SC [SC_OFF.main] SENSCOR_Y_IIRHP FMs:[4] is not in the correct configuration
ISI_ITMY_ST2_SC [SC_OFF.main] SENSCOR_Y_IIRHP FMs:[4] is not in the correct configuration
ISI_ETMY_ST1_SC [SC_OFF.main] SENSCOR_GND_STS_Y_WNR FMs:[6] is not in the correct configuration
ISI_ETMY_ST1_SC [SC_OFF.main] SENSCOR_GND_STS_Y_WNR FMs:[6] is not in the correct configuration

I've tried to track down where exactly the problem is coming from, but haven't been able to figure it out yet.  It looks like the expected configuration just does not match with how they're currently set.  I will need to consult with the SEI folks tomorrow to sort this out.  In the mean time, I'm leaving all of the above nodes paused.

 

 

Comments related to this report
thomas.shaffer@LIGO.ORG - 07:52, Monday 09 April 2018 (41339)

A note on the SC nodes:

Since these new SC nodes are still in a bit of a testing phase, I don't think all of the filters that will be used are in the configuration file. One way we could get around this, until the config file is set exactly how the SEI wants it, is to remove the check temporarily. I'm hesitant to remove it entirely, but that might be best since it doesn't allow for any testing of new filters.

jameson.rollins@LIGO.ORG - 07:58, Monday 09 April 2018 (41340)

As of 7:50 am this morning (after I restarted 5 nodes last night):

HPI_BS              enabled    active     2018-04-08 14:48:46-07:00
HPI_ETMX            enabled    active     2018-04-08 14:48:05-07:00
HPI_ETMY            enabled    active     2018-04-08 15:55:18-07:00
HPI_HAM1            enabled    active     2018-04-08 14:42:32-07:00
HPI_HAM2            enabled    failed     2018-04-08 14:40:54-07:00
HPI_HAM3            enabled    active     2018-04-08 14:41:09-07:00
HPI_ITMX            enabled    active     2018-04-08 14:48:05-07:00
HPI_ITMY            enabled    failed     2018-04-08 14:48:05-07:00
ISI_BS_ST1          enabled    active     2018-04-08 14:49:54-07:00
ISI_BS_ST1_BLND     enabled    active     2018-04-08 15:38:51-07:00
ISI_BS_ST1_SC       enabled    active     2018-04-08 16:16:57-07:00
ISI_BS_ST2          enabled    failed     2018-04-08 14:49:54-07:00
ISI_BS_ST2_BLND     enabled    active     2018-04-08 15:38:51-07:00
ISI_BS_ST2_SC       enabled    active     2018-04-08 16:16:56-07:00
ISI_ETMX_ST1        enabled    failed     2018-04-08 14:47:10-07:00
ISI_ETMX_ST1_BLND   enabled    active     2018-04-08 15:34:22-07:00
ISI_ETMX_ST1_SC     enabled    active     2018-04-08 16:16:57-07:00
ISI_ETMX_ST2        enabled    active     2018-04-08 14:47:10-07:00
ISI_ETMX_ST2_BLND   enabled    active     2018-04-08 15:34:21-07:00
ISI_ETMX_ST2_SC     enabled    active     2018-04-08 16:16:56-07:00
ISI_ETMY_ST1        enabled    active     2018-04-08 14:47:10-07:00
ISI_ETMY_ST1_BLND   enabled    active     2018-04-08 15:37:45-07:00
ISI_ETMY_ST1_SC     enabled    active     2018-04-08 16:16:57-07:00
ISI_ETMY_ST2        enabled    active     2018-04-08 14:47:10-07:00
ISI_ETMY_ST2_BLND   enabled    failed     2018-04-08 15:37:45-07:00
ISI_ETMY_ST2_SC     enabled    active     2018-04-08 16:16:57-07:00
ISI_HAM2            enabled    active     2018-04-08 14:40:54-07:00
ISI_HAM2_SC         enabled    failed     2018-04-08 16:16:57-07:00
ISI_HAM3            enabled    failed     2018-04-08 14:41:09-07:00
ISI_HAM3_SC         enabled    active     2018-04-08 16:16:56-07:00
ISI_ITMX_ST1        enabled    active     2018-04-08 14:47:10-07:00
ISI_ITMX_ST1_BLND   enabled    active     2018-04-08 23:17:14-07:00
ISI_ITMX_ST1_SC     enabled    active     2018-04-08 16:16:57-07:00
ISI_ITMX_ST2        enabled    active     2018-04-08 23:17:14-07:00
ISI_ITMX_ST2_BLND   enabled    failed     2018-04-08 15:33:53-07:00
ISI_ITMX_ST2_SC     enabled    active     2018-04-08 16:16:57-07:00
ISI_ITMY_ST1        enabled    active     2018-04-08 14:47:10-07:00
ISI_ITMY_ST1_BLND   enabled    active     2018-04-08 15:33:12-07:00
ISI_ITMY_ST1_SC     enabled    failed     2018-04-08 16:16:57-07:00
ISI_ITMY_ST2        enabled    active     2018-04-08 14:47:10-07:00
ISI_ITMY_ST2_BLND   enabled    failed     2018-04-08 15:33:37-07:00
ISI_ITMY_ST2_SC     enabled    active     2018-04-08 16:16:57-07:00
SEI_BS              enabled    active     2018-04-08 14:48:45-07:00
SEI_ETMX            enabled    active     2018-04-08 14:47:26-07:00
SEI_ETMY            enabled    active     2018-04-08 23:17:13-07:00
SEI_HAM2            enabled    active     2018-04-08 14:40:53-07:00
SEI_HAM3            enabled    active     2018-04-08 14:41:08-07:00
SEI_ITMX            enabled    failed     2018-04-08 14:47:26-07:00
SEI_ITMY            enabled    active     2018-04-08 14:47:26-07:00
SUS_BS              enabled    active     2018-04-08 23:17:13-07:00
SUS_ETMX            enabled    active     2018-04-08 14:47:27-07:00
SUS_ETMY            enabled    active     2018-04-08 14:47:27-07:00
SUS_IM1             enabled    active     2018-04-08 14:05:38-07:00
SUS_IM2             enabled    failed     2018-04-08 14:05:38-07:00
SUS_IM3             enabled    failed     2018-04-08 14:05:38-07:00
SUS_IM4             enabled    failed     2018-04-08 14:05:38-07:00
SUS_ITMX            enabled    active     2018-04-08 14:47:27-07:00
SUS_ITMY            enabled    active     2018-04-08 23:17:13-07:00
SUS_MC1             enabled    active     2018-04-08 23:17:14-07:00
SUS_MC2             enabled    active     2018-04-08 14:40:11-07:00
SUS_MC3             enabled    failed     2018-04-08 14:40:11-07:00
SUS_PR2             enabled    failed     2018-04-08 14:40:11-07:00
SUS_PR3             enabled    failed     2018-04-08 14:40:11-07:00
SUS_PRM             enabled    active     2018-04-08 14:40:11-07:00
SUS_RM1             enabled    failed     2018-04-08 13:45:41-07:00
SUS_RM2             enabled    active     2018-04-08 13:45:48-07:00
SUS_TMSX            enabled    active     2018-04-08 14:53:45-07:00
SUS_TMSY            enabled    active     2018-04-08 14:53:46-07:00

Including the five nodes I restarted last night, that's 23 seg faults out of 68 nodes in roughly 18 hours = 6 hour MTTF.  That's higher than it was previously.  I'm reverting all nodes back to h1guardian0.

jameson.rollins@LIGO.ORG - 08:26, Monday 09 April 2018 (41342)

All nodes have been reverted back to h1guardian0

jonathan.hanks@LIGO.ORG - 18:04, Tuesday 10 April 2018 (41371)
I have attached a pdf with a breakdown of stack traces and pids, so that we can see what the causes of the failures were.
Non-image files attached to this comment
Displaying report 1-1 of 1.