Reports until 15:35, Monday 09 April 2018
H1 SUS
betsy.weaver@LIGO.ORG - posted 15:35, Monday 09 April 2018 - last comment - 15:22, Tuesday 10 April 2018(41346)
WBSC9 ETMX QUAD halves back together

Today, Travis and I finished assembling the ETMX lower reaction chain.  We assembled the PenRe mass in the structure, attaching the balance of parts to make the weight from last week including AOSEMs, cables, and cable routing brackets.  We then installed the new annular AERM07 mass below the PenRe in the lower structure and adjusted it in it's 6 DOF's by eye before suspending it.  We then reclamped everything and rolled the main lower chain up to it.  A quick lift via the Genie duct jack and we set the main lower structure and newly fiber'ed masses into the trolley with the reaction set.  We added the UIM and PUM magnets/flags (set with polarities per the QUAD controls poster), and then shoved the 2 structures together and fastened them.

We wrapped the now complete lower unit and rolled it to the chamber side.  After attaching some of the LSAT lifting blocks, we staged the Genie duct jack so that we are ready to install it on the arm and into the chamber tomorrow.

Comments related to this report
betsy.weaver@LIGO.ORG - 15:39, Monday 09 April 2018 (41347)

Note - Travis noticed a door bolt sitting in the BSC9 flange in the unused hole at 3 o'clock.  The washer from the bolt (which held nothinglooked to be rubbing funny on the o-ring so he removed it.  The vacuum crew will need to inspect this after we remove the install arm.  (Note, the install arm and stiffening flanges cover most of the right side of holes and o-ring on this chamber, except for a ~6" gap at 3 o'clock.  There are o-ring covers everywhere else.  This bolt should not have been in this hole, since it served no purpose.)

betsy.weaver@LIGO.ORG - 15:22, Tuesday 10 April 2018 (41364)

From Chandra and Kyle who inspected this o-ring portion yesterday late afternoon:

Kyle and I inspected the o-ring and deemed it ok to reuse. Kyle peeled away a
sliver of viton material that was hanging off of the o-ring. To the naked eye
the surface looks ok. We will take note of this when we install the door and
pump down the annulus volume.