Electric field meter common mode rejection and dark noise

[Rich A, Calum T, Luis S, Craig C, Koji A, Georgia M]

We have begun testing and characterising the electric field meter (EFM) brought over from Caltech. The first photo shows the EFM with the sensing plates shorted. All of this activity took place in the optics lab.

We used the SR785 to take noise spectra with the plates grounded, and of the ambient electric field (or acoustic environmental noise) for the X and Y plates. These spectra are shown in the first plot, the y data have 25 averages while the X data has one. The grounded spectra are in agreement (the 60 Hz harmonics are present in the blue x trace also) which makes sense, however I’m not sure why there is a significant difference between the x and y ambient spectra.

We then tuned the digital potentiometers, using the Arduino and Luis' code, to optimise the common mode rejection between the X+ and X- plates and the Y+ and Y- plates. To do this we attached the calibration plates over the sensor plates (but electrically isolated), and drove the common mode with a 1V signal. This configuration is shown in the second photo. The transfer functions to the common mode, and to a single plate, are attached for the Y plates. (the X data did not save properly and we did not have time to go back and get it. If I remember correctly we had ~47 dB of common mode rejection on the X plates, but please correct me if this is wrong). We achieved roughly 60 dB of common mode rejection between the y plates at 1 kHz, though this gets worse at higher frequencies.

Images attached to this report
Comments related to this report
rainer.weiss@LIGO.ORG - 12:29, Wednesday 11 April 2018 (41379)SYS
Good that you got the device together so fast. The noise curves for x should be lower and the ones for y do not make sense. I am wondering about the calibration for electric field. You will need to take account of the copper button. The field between the calibration plate and the button will be higher than in the region between the plates outside of the button. The ratio of the fields in the two places will be in the inverse ratio of the gap space. One will need to estimate the induced surface charge on the sense plate by adding the contribution for the surface charge times area of the two regions with different gap spacing. If this is not done the field sensitivity of the device will be estimated as too high.
georgia.mansell@LIGO.ORG - 12:50, Wednesday 11 April 2018 (41381)

We retook the noise spectra, the ambiant Y trace is fixed, added the SR785 noise, and made the number of averages consistent (15).

We also improved the common mode rejection between the +X and X plates, and added that transfer function to the log post. Note that the hexidecimal digital potentiometer values are 058e and 0550 for the X and Y directions respectively. This corresponds to a wiper-to-b resistance of R_x = 7773.44 Ohms and R_y = 6562.5 Ohms.
 
Also measured the capacitance from sensor plates to body of the cube (ground):
X+ 18 pF
X- 18.4 pF
Y+ 19.4 pF
Y- 19.3 pF