h1susey models compiled with -O3 optimization

WP7472 h1susey models recompiled with -O3 optimization

Dave, Miriam

As part of Miriam's glitch investigation, I rebuilt all the h1susey models (h1iopsusey, h1susetmy, h1sustmsy, h1susetmypi) with the -O3 optimization flag. All the models were restarted at 13:41 PDT.

As Rolf found when he did this at LLO, the optimization change sped up the models by a few microseconds. For example h1susetmy was running at 36uS and is now running at 33uS.

Travis suggested we keep the watchdogs active on ETMY and TMSY, and therefore the IOP has its DACKILL bit set (STATEWORD = 128).