Displaying report 1-1 of 1.
Reports until 13:51, Thursday 12 April 2018
H1 SQZ (SQZ)
nutsinee.kijbunchoo@LIGO.ORG - posted 13:51, Thursday 12 April 2018 - last comment - 14:41, Thursday 12 April 2018(41407)
Double-beam hunting

Robert, Sheila, Nutsinee

Today we removed a view port cover on HAM5 north door (faraday side) to look for the IFO beam reflected off AR side of the thin film polarizer. Attached a couple photos we took with our IR camera (Nikon D7100 with IR filter removed)-- We found the beam hitting the HAM6 side of the ZM2 cage. The beam moved towards HAM4 when we did positive yaw on SR2 and moved up when we did negative pitch. This is consistent with how the rejected polarization beam moved in HAM6.

According to Koji's calculation and Corey Austin's response to our alog last night (alog41403) we suspect that our wedge is in the opposite direction.

Images attached to this report
Comments related to this report
corey.austin@LIGO.ORG - 14:41, Thursday 12 April 2018 (41408)

I changed the direction of the wedge on the TFP in the model and found that the ghost beam lands on the bracket for ZM2 as was seen IRL by Nutsinee, Robert, and Sheila.

Non-image files attached to this comment