Displaying report 1-1 of 1.
Reports until 11:09, Monday 10 September 2012
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:09, Monday 10 September 2012 - last comment - 11:20, Tuesday 11 September 2012(4143)
H1 MC1 Transfer Functions - Starting now

While I am at LLO, I am running the Phase 2a chamberside testing of MC1.  I have read the log and see no reasons why I should not actualte on MC1 chamberside.  I am aware that people are on the floor and even possibly working on the same table.  I'll look at the DQ as I go.  Please email me (or call my cell) if you need to.

Comments related to this report
betsy.weaver@LIGO.ORG - 06:35, Tuesday 11 September 2012 (4150)

Discovered that the IOP watchdog kept tripping since it was not bypassed.  Dave will boot h1sus2a front end this morning in order to implement the bypass.

betsy.weaver@LIGO.ORG - 11:20, Tuesday 11 September 2012 (4152)

Now that Dave reportedly bypassed the IOP, I am restarting TFs.