Reports until 10:28, Monday 16 April 2018
H1 PSL (PSL)
cheryl.vorvick@LIGO.ORG - posted 10:28, Monday 16 April 2018 (41463)
PSL Status Report - Weekly - FAMIS 7486

Laser Status:
SysStat is good
Front End Power is 0.0003016W (should be around 30 W)
HPO Output Power is 0.7154W
Front End Watch is GREEN
HPO Watch is RED

PMC:
It has been locked 2 days, 18 hr 26 minutes (should be days/weeks)
Reflected power = 20.46Watts
Transmitted power = 42.4Watts
PowerSum = 62.87Watts.

FSS:
It has been locked for 2 days 23 hr and 39 min (should be days/weeks)
TPD[V] = 2.293V (min 0.9V)

ISS:
The diffracted power is around 0.13% (should be 3-5%)
Last saturation event was 0 days 3 hours and 43 minutes ago (should be days/weeks)

Possible Issues: (all accounted for, due to PSL commissioning)
Front End Power is Low
PMC reflected power is high
ISS diffracted power is Low
LRA out of range, see SYSSTAT.adl