Output beam study, clipping?

Aidan, Daniel V-H., TVo, Dan B., Terra

This is the initial analysis of the HAM6 output beam scan we did last weekAttached is the overall picture, in the style of LLO's beam study.

Measurements are done in HAM6 during single bounce configuration (no TCS) either directly in beam or using pickoff. Data is then fit by varying input beam parameters and, to some degree, OM optical/path length parameters. These are compared against the original output beam design. (There is a caveats to this, see below.) Since there was large astigmatism, what I show is beam fit prioritized to fit vertical measurements. [R,w] directly after SRM for design and vertical fits shown in plot. X-axis distances are in meters from SRM.

Main points:

Caveat/to do: the design beam includes a 50km ITM lens, so I need to subtract that for more meaningful comparison; in the works.

For reference, the parameters used are:

 

Images attached to this report
Comments related to this report
terra.hardwick@LIGO.ORG - 10:20, Wednesday 18 April 2018 (41517)

Adding screen shot of raw data from beam scanner: horizontal data on top, vertical on bottom. A one-sided pedestal on the right side of top plot can be seen. This measurement was taken ~10 inches from the edge of the ISI table closest to the septum window in the beam path as it enters HAM6 from SRM to OM1.

Images attached to this comment
aidan.brooks@LIGO.ORG - 09:24, Thursday 19 April 2018 (41541)

I enhanced the bottom image [vertical cross-section of beam] and rescaled it to the same horizontal and vertical scale as the top image [horizontal cross-section of beam], then I pasted this over the top image. Horizontal cross section = thin white line. Vertical cross-section = thick black line. 

This highlights the excess power in the right hand side of the horizontal cross-section.

Images attached to this comment