Displaying report 1-1 of 1.
Reports until 18:03, Tuesday 17 April 2018
H1 PSL (PSL)
richard.savage@LIGO.ORG - posted 18:03, Tuesday 17 April 2018 (41500)
PMC swap complete

PeterK, JasonO, EdM, RickS

Today, we swapped out the original PMC for one of the new "All-bolted" PMCs (see LIGO-T1700543-v2), S/N007 (photos attached)

We aligned the PMC, FSS and ISS paths, locked the servos and adjusted the light levels and gains.

When we increased the power into the PMC to ~ 20 W, we noticed that the modematching to the PMC was degrading.

We found that the first turning mirror downstream of the new 70-W amplifier is damaged (extremely bright glow where the beam is reflecting from the surface (if you zoom on the photo below you will see the bright spot on the surface - 9:00, slightly left of center).  This is likely the cause of the change in the beam characteristics with power.

We plan to swap this optic out first thing tomorrow.

 

Images attached to this report