jeffrey.kissel@LIGO.ORG - posted 18:30, Tuesday 17 April 2018 (41503)
H1SUSOPO Update: V2 OSEM Replacement is Successful, TFs Look Good, especially with HAM6 ISI Unlocked
J. Kissel

Following up on all the work from yesterday replacing the V2 OSEM on H1SUS OPO (ID of problem: LHO aLOG 41468, Replacement LHO aLOG 41470), I've had a bit of time between HAM6 SQZ Team Closeout Activity to grab a set of undamped Euler basis TFs.

Attached are the results.

One can see -- especially in pitch -- that swapping the V2 OSEM has moved out the PD-to-Coil cross-coupling zero to the typical ~10 Hz, and fixed the problem.

The TFs are pretty noisy, but not unexpectedly so: while the ISI was unlocked, the chamber was still half-open letting in SQZ light, so I expect purge was still flowing heavily over the OPOS.

I'd like to get
    - A Repeat of the Euler basis TFs,
    - OSEM basis TFs,
    - Damped TFs,
one morning when we have the chamber door parachutes completely closed, and pulled away from the ISI (as was true for the 2018-04-02 data).