chandra.romel@LIGO.ORG - posted 14:30, Wednesday 18 April 2018 - last comment - 22:59, Wednesday 18 April 2018(41524)
CP4 gas N2 heater

Yesterday Ken D. with K&N Electric and Richard M. installed the new 28 A, 480 VAC variable transformer at MY to bypass the problematic SCR and power the GN2 heater. Today Kyle, Gerardo and I turned it on. We first flowed unheated, vaporized GN2 and let the temperature settle (~20C) and then ramped the variac to 40% power, until the temperature stabilized to ~85C. After lunch I increased it to 45% power and will wait till it stabilizes and will continue that trend until we reach 160C. The GN2 flow fluctuates between 20-60 scfhx100 with one full turn on draw valve. We may need to increase flow over time as the vaporizer cools down and the Dewar level decreases. The exhaust temperature is currently 65C.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 16:31, Wednesday 18 April 2018 (41528)

45% power on variac yields ~100C (on TC:  H0:VAC-MY_CP4_TE253A_REGEN_TEMP_DEGC).

chandra.romel@LIGO.ORG - 22:59, Wednesday 18 April 2018 (41535)

Note that the CP4 Dewar is about 80% full.