Helium leak tested nipple-to-GV 16.5" joint as well as nipple welds with background of 2 x 10-9 torr*L/sec -> OK. Currently there is a zero-length reducer with a 1 1/2" valve installed in place of the nominal 2500 L/sec ion pump which has been removed and is being refurbished.
Leak testing related to install from aLOG 41523
Baffle nipple/housing is SN006. Chevron baffle assembly is SN004.