H1 SYS
(AOS, DAQ, IOO, ISC, OpsInfo, SEI, SQZ, SUS, SYS, TCS)
J. Bartlett, P. King, J. Kissel, H. Radkins, T. Vo
We've reviewed the SDF system prior today's scheduled fast front-end reboot. We've only accepted things we can confirm we know are necessary because of physical changes to the IFO. Otherwise, we reverted to the safe values and/or left things as DIFFs (because the reboot will revert).
Kissel, Vo (ISC / SUS / IMC)
- Accepted outputs and offsets on for all SUS by putting them in the ALIGNED state (i.e. when all OUTPUT switches are ON; a few new or neglected SUS needed this, like RMs, ZMs, OFI OPO), because the watchdog protects the system upon reboot.
- Accepted a few new misalignment offset values (SRM, ITMs, PRM) because we've physically changed the alignment of these suspensions during the Sep-Dec 2017 corner vent, and the misaligned position has now been confirmed by a few months worth of corner station commissioning
- SR3 optical lever input gains to ZERO until we make the front-end changes need to get it up and running (see LHO aLOG 41547)
- In ISC land, accepted dark offsets on AS A & B and OMC QPD (remeasured to make stuff work in air, will likely have to be remeasured in the future anyways)
- 180 phase change in ASC OMC DC centering loops because of the tip-tilt actuator sign flip (LHO aLOG 41441)
Radkins (SEI)
- Cleared out by Hugh -- most diffs are because some chambers are locked, and/or the sensor correction configuration is OFF which is "abnormal" for observing
Bartlett, King (PSL)
- FSS and PMC are stable, so J. Bartlett & P. King accepted the DIFFs on this.
- ISS and DBB
We're OK to Go for reboot of front-ends.