End Y Timing Comparator Modification Complete
Taking advantage of the pump down we retrieved, modified, and reinstalled the timing comparator at end Y.  The following modifications were applied to unit S1201222:

LIGO-E1800008: ECR: Timing Comparator replace 5V regulator with seperate DC Power board

LIGO-E1200034: Timing RF Counter/Comparator Software Release

LIGO-E1700246: ECR: Add frequency counter channels to timing comparator

One down, three to go!

Comments related to this report
marc.pirello@LIGO.ORG - 17:57, Tuesday 24 April 2018 (41652)

Reinstalled proper Timing Comparator S1107952 into CER and returned spare to the rack.  *Spare still requires upgrade

Pulled, Upgraded and Reinstalled MSR Timing Comparator S1201224.

No front ends were harmed in this operation. 

Three Timing Comparators done, one remains unmodified at X end.

Displaying report 1-1 of 1.