jeffrey.kissel@LIGO.ORG - posted 15:14, Thursday 26 April 2018 (41696)
HAM6 H1 SUS HTTS Ready for Doors
J. Kissel, T. Shaffer

TJ scanned over the OMs this morning, looking at and adjusting eddy current damping magnets and earthquake stops on all HTTS in HAM6 -- OM1, OM2, OM3, and ZM1. Then, he took the full suite of transfer functions to confirm all where free of rubbing. They're all free of rubbing.

ZM1 still shows a bit of abnormal dynamics in its yaw to yaw DOF (abnormal w.r.t. to all other HTTSs, showing a second resonance in yaw other that the expected primary mode, and the primary mode is a bit lower in frequency than expected), but it will work well enough.

I've processed TJ's results, and they're attached.

Also, I've checked the OSEM centering -- looks good. 

Also, also, checked the high-frequency spectra -- looks good enough. Interestingly (is it really? do we wanna know? do we care enough to fix it?) ZM1 shows much more lines, junk, and ~6-7 kHz humps where the OMs do not. Fil & CDS crew have yet to perform ground loops checks, so they may identify and fix a problem or two that may alleviate this issue.

Regardless, I decree the HAM6 HTTSs are good enough for us to close doors.