J. Kissel Since HAM5 has been up-and-down to air several times since ZM2 and the actuators for the OFI have been installed, it's taken us a while to get their first in-vacuum, clean set of transfer functions. Today is the day! ...Just before we vent again this morning. Raw data lives here: /ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/ZM2/SAGM1/Data/ 2018-04-30_1545_H1SUSZM2_M1_WhiteNoise_L_0p02to50Hz.xml 2018-04-30_1545_H1SUSZM2_M1_WhiteNoise_P_0p02to50Hz.xml 2018-04-30_1545_H1SUSZM2_M1_WhiteNoise_Y_0p02to50Hz.xml /ligo/svncommon/SusSVN/sus/trunk/OFIS/H1/OFI/SAGM1/Data 2018-04-30_1547_H1SUSOFI_M1_WhiteNoise_L_0p02to50Hz.xml 2018-04-30_1547_H1SUSOFI_M1_WhiteNoise_T_0p02to50Hz.xml 2018-04-30_1547_H1SUSOFI_M1_WhiteNoise_Y_0p02to50Hz.xml Will process in detail later, but as expected the results look great.