Displaying report 1-1 of 1.
Reports until 18:00, Friday 04 May 2018
H1 ISC (IOO)
daniel.sigg@LIGO.ORG - posted 18:00, Friday 04 May 2018 (41852)
EOM Drivers moved outside PSL enclosure

Fil Peter Rick Jason Daniel

We moved the EOM drivers from under the PSL table to the bottom of the PSL-R2 rack. The setup itself is still the same until we get the RF combiner/amplifier. Before connecting back to the EOM, we remeasured the RF power using the same settings of 23.4 dBm and 27.0 dBm for 9 and 45 MHz, respectively. As a comparison, we also give the numbers from Koji's alog 41435.

Frequency old alog 41435 @rack PSL-R2 @ EOM Cable loss Difference
9.1 MHz 23.56 dBm 23.49 dBm 23.33 dBm 0.16 dB –0.07 dB
24.07 MHz 24.60 dBm 25.33 dBm 24.90 dBm 0.43 dB +0.30 dB
45.5 MHz 23.76 dBm 23.84 dBm 23.48 dBm 0.36 dB –0.28 dB
118 MHz 9.84 dBm 10.22 dBm 9.66 dBm 0.56 dB –0.18 dB

The cable loss for the 24 MHz signal seems a little high and might be due to an imperfect VSWR. Otherwise, the RF levels are close, but the RF phases will have changed.

More details in T1800196.