T240 & STS Centering (FAMIS #6415)
STS
2018-05-07 13:21:57.355505
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS A DOF Y/V = -4.561 [V]
STS A DOF Z/W = 5.58 [V]

All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -1.631 [V]
STS B DOF X/U = 0.183 [V]
STS B DOF Y/V = 0.917 [V]
STS B DOF Z/W = -0.462 [V]
STS C DOF X/U = 0.299 [V]
STS C DOF Y/V = -0.139 [V]
STS C DOF Z/W = 1.083 [V]
STS EX DOF X/U = -0.108 [V]
STS EX DOF Y/V = 0.446 [V]
STS EX DOF Z/W = 0.219 [V]
STS EY DOF X/U = 0.226 [V]
STS EY DOF Y/V = -0.035 [V]
STS EY DOF Z/W = 0.531 [V]
Assessment complete.



T240
Averaging Mass Centering channels for 10 [sec] ...
2018-05-07 13:27:56.363239

There are 19 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 1 DOF Z/W = -0.414 [V]
ETMX T240 2 DOF Y/V = -0.575 [V]
ETMX T240 2 DOF Z/W = -0.723 [V]
ETMX T240 3 DOF Z/W = 0.403 [V]
ITMX T240 1 DOF X/U = -1.033 [V]
ITMX T240 2 DOF X/U = -0.374 [V]
ITMX T240 3 DOF X/U = -1.208 [V]
ITMY T240 1 DOF X/U = -0.363 [V]
ITMY T240 1 DOF Y/V = -0.502 [V]
ITMY T240 1 DOF Z/W = -0.383 [V]
ITMY T240 2 DOF Z/W = -0.582 [V]
ITMY T240 3 DOF X/U = -1.121 [V]
ITMY T240 3 DOF Y/V = -0.307 [V]
ITMY T240 3 DOF Z/W = -1.553 [V]
BS T240 1 DOF X/U = -0.364 [V]
BS T240 1 DOF Y/V = -0.432 [V]
BS T240 2 DOF Z/W = -0.417 [V]
BS T240 3 DOF Y/V = -0.47 [V]
BS T240 3 DOF Z/W = -0.638 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.164 [V]
ETMX T240 1 DOF Y/V = 0.242 [V]
ETMX T240 2 DOF X/U = -0.216 [V]
ETMX T240 3 DOF X/U = -0.17 [V]
ETMX T240 3 DOF Y/V = 0.03 [V]
ETMY T240 1 DOF X/U = -0.063 [V]
ETMY T240 1 DOF Y/V = 0.175 [V]
ETMY T240 1 DOF Z/W = -0.123 [V]
ETMY T240 2 DOF X/U = 0.013 [V]
ETMY T240 2 DOF Y/V = -0.135 [V]
ETMY T240 2 DOF Z/W = -0.012 [V]
ETMY T240 3 DOF X/U = -0.141 [V]
ETMY T240 3 DOF Y/V = -0.066 [V]
ETMY T240 3 DOF Z/W = 0.142 [V]
ITMX T240 1 DOF Y/V = -0.261 [V]
ITMX T240 1 DOF Z/W = -0.227 [V]
ITMX T240 2 DOF Y/V = -0.262 [V]
ITMX T240 2 DOF Z/W = -0.16 [V]
ITMX T240 3 DOF Y/V = -0.098 [V]
ITMX T240 3 DOF Z/W = -0.209 [V]
ITMY T240 2 DOF X/U = -0.108 [V]
ITMY T240 2 DOF Y/V = -0.045 [V]
BS T240 1 DOF Z/W = -0.018 [V]
BS T240 2 DOF X/U = -0.232 [V]
BS T240 2 DOF Y/V = 0.088 [V]
BS T240 3 DOF X/U = -0.173 [V]
Assessment complete.

   Chamber closeout and Quad install work is underway at this time.