Displaying report 1-1 of 1.
Reports until 17:47, Monday 14 May 2018
LHO VE
chandra.romel@LIGO.ORG - posted 17:47, Monday 14 May 2018 - last comment - 17:56, Monday 14 May 2018(41980)
CP4 pressure

CP4 pressure on 450 l/s turbo pump is 2.5e-9 Torr. Will take RGA scans tomorrow. Bake enclosure will be removed tomorrow.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 17:56, Monday 14 May 2018 (41981)

Attached is an SEM analog scan (in red) from LLO's cold, isolated CP4 (pumped with small 55 or 75 l/s IP) at their EX in comparison with the preliminary scan (in black) Kyle took last week of LHO's baked CP4 pumped by 450 l/s turbo. Note that LLO's scan is from an SRS model and LHO's is from a Pfeiffer Prisma Plus model so the Torr to amp ratios are different.

Images attached to this comment
Displaying report 1-1 of 1.