Optical Lever Centering int the CS
Ed, Jason
ITMY Oplev centering seems to be achieved by having to rail the translation stage responsible for pitch. This will eventually have to be addressed at a time in the future and will require some fairly invasive work/permits.
ITMX Oplev centering went well
PR3 Oplev centering didn't look achievable until it was determined and discovered that the Oplev LASER had been switched off. Once switched on, proper centering was rather easily achieved.