jim.warner@LIGO.ORG - posted 10:27, Friday 18 May 2018 - last comment - 13:40, Friday 18 May 2018(42045)
ETMY HEPI Y tilt decoupling

After Hugh's HEPI-Oplev yaw decoupling, I wanted to look at HEPI Y - ISI RX/RY tilt decoupling on this chamber. I used the same approach we've used in the past on the ISIs, using the ISI T240s as a witness. I drove HEPI at low frequency, with the ISI isolated with high blends to lock the stages to HEPI. If the there is any Y to RX/RY coupling it shows up as a g/w^2 tilt in the HEPI Y IPS to ISI X/Y T240 transfer function.  For the T240 X dof, I saw that pretty clearly. For Y, the low frequency component is more like 1/f-f^1.5, instead of 1/f^2.

The attached plot shows the transfer functions (before & after) from HEPI Y IPS to the ISI X/Y T240s. In order to get the coefficient for the correction, the transfer functions need to be put into tilt units (dividing by g/w^2) and the T240s are put into displacement, so the magnitude y-axis is rad/m-rthz. After getting the units right, I just got an eyeball average of the flat, low frequency component for the Y-RY transfer function. The difference between the lower blue (measured before the correction) and yellow (measured after) curves are the improvement I was able to get. I looked at the IPS Y to oplev yaw and pitch tfs to see if there was any difference, but there was no change.

Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 13:40, Friday 18 May 2018 (42074)

These are the same transfer functions, but not in tilt units. These are the transfer functions from HEPI IPS Y to ISI T240 X/Y. Because the T240s readout in m/s, I've had to multiply by a pole at 0 to get the tfs into m/m. I've also included the g/w^2 transfer function (divided by 1000 to keep the scale sane) for comparison.

Images attached to this comment