WP7558 - update
h1fw2 ran over the weekend with the cpu affinity settings.  The retransmit rate was higher than expected.  However it is still a lower rate than h1fw0, so a work permit is filed to update the other debian 8 daqd systems tomorrow.

For tonight h1fw2 will run with some minor tweaks to the crc checking code that remove some runtime table generation.  h1fw2 has also been configured to request per thread cpu affinity which seems to do a good job at keeping threads from migrating across all the cores.  The behavior of h1fw2 tonight will impact how many of the changes are going into h1fw0 tomorrow.