Displaying report 1-1 of 1.
Reports until 17:49, Wednesday 23 May 2018
H1 ISC (ISC)
thomas.vo@LIGO.ORG - posted 17:49, Wednesday 23 May 2018 - last comment - 08:45, Thursday 24 May 2018(42165)
IMC UGF Adjusted

Sheila, TVo

We noticed that the boost filter would cause the IMC to oscillate so we checked the OLTF again and found the UGF at 4 kHz, so we added +15 db to the servo gain and found a new UGF of about 30 kHz.  This is probably due to the new EOM changing the modulation depth. 

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 21:30, Wednesday 23 May 2018 (42170)

This seems high. The modulation depth is estimated to be only 3 times lower.

thomas.vo@LIGO.ORG - 08:45, Thursday 24 May 2018 (42172)

Yeah it did seem odd, but we reduced the gain by 4db here previously. So in the end it's about +11db which is close to what we'd expect from the EOM swap, maybe.

Displaying report 1-1 of 1.