Reports until 19:02, Sunday 27 May 2018
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:02, Sunday 27 May 2018 (42200)
work on PRMI/DRMI locking today

Today I spent some time on alignment of PRMI and the SRC, as well as some guardian things that I hope will make these alignments a little easier.  After the alignment DRMI locked easily on 1F (I haven't tried to engage alignment loops).

I did a walk of the PRMI alignment using PRM, PR2 and BS.  The build ups in PRMI are now POP90 norm 73.5 and POP18 48.3, which is 40% better than earlier this week for POP90 and 60% better for POP18.  These builds ups are in the same ball park as the buildups that we had Sept 10th 2015 at 5:26 UTC when POP 90 norm was 84 and pop 18 was 56.  I think that we have had multiple modulation depth changes since Sept 2015.  It would be good to search for a more recent time when PRMI was locked without arms, and also to calibrate these into sideband gains. 

After aligning PRMI, I had a look at the alignment in HAM4/5/6.  

After that DRMI locked easily.  The MICH and SRCL gains were fine with UGFs of 6.3Hz and 35Hz, the PRCL gain seemed low, I increased it by 86% for a ugf of 65 Hz, and also added a gate_valve_flag to the guardian that can be used to identify that the arms are not controlled when ETMX is aligned.  

I also spent some time today on things that I think could help make our initial alignment process better (both in the short term while we are missing cameras and once we get back to the full ifo):

For now, I think that the best way to align PRMI is to use PRX and manually walk PRM and PR2 to maximize the build ups on POP, then choose the WFS_CENTERING_MICH_BRIGHT state and adjust the beam splitter to maximize the power on AS QPDs.

Images attached to this report
Non-image files attached to this report