Displaying report 1-1 of 1.
Reports until 20:55, Thursday 24 May 2018
H1 TCS (TCS)
marie.kasprzack@LIGO.ORG - posted 20:55, Thursday 24 May 2018 - last comment - 15:47, Friday 01 June 2018(42182)
Ring heater- initial Hartmann sensor measurements

[Marie, Aidan, Alexei, Dan, TJ]

As mentioned above in alog 42171, we set up a ring heater measurement last night to observe the response of the HWS. The ring heater was switched on with 2 W total power dissipated (1W in the upper segment, 1W in lower segment) for 8 hours. Results are encouraging:

In figure 1, we can clearly see the effect of  thermal transient from the ring heater on the spherical power of the HWS beam phase. The measured amplitude of the maximum phase deformation (~ -80 udiopters) corresponds to the prediction of the model, once we roughly correct for the magnification of the beam on the test mass (we measured it yesterday to be about 23.5 instead of 20.5 in the model). It indicates that the HWS might be probing the test mass correctly. However, a more careful analysis is required.
The spherical power from the HWS indicates a large drift at the beginning. We think it is partly due to the thermal stabilization of the HWS sensor itself. The total slope over the first 6 hours is about 40 udiopters, which is large compared to the effect of the ring heater. There is a cross-coupling between the spherical power and prism X, on top of a beam drift indicated by the prism X/Y power (corresponding to the tilts of the test mass).

In figures 2 to 5, we can see the wavefront measurements from the HWS at different stages:  after the sensor thermal drift (+6h on the time scale of figure 1), when the deformation is maximum (+9h), before the ring heater is switched off (+14h) and at the end of the measurement (+17h). The code needs to be changed to see more clearly the phase below 90 nm difference. 


****

Today we worked on the beam optimization by adjusting the beam alignment and initial iris aperture. One issue is the axis-symmetric reduction of the iris aperture doesn't translate into a symmetric effect in the return beam power distribution. It indicates that the beam is clipping and we are not imaging its center. However, the number of centroid has increased with respect to yesterday (+ 30%), as well as the intensity homogeneity on the HWS.

As it is inefficient to check the performance of the setup with ring heater tests, due to the large amount of time they take, today we looked for faster figures of merit. One of them could be the cross-coupling between the prism X/Y and the spherical power. If the coupling is low, the beam is more likely to be aligned on the test mass. We injected a yaw oscillation at ETMY M0 (10 urad at 0.03 Hz). When optimizing the homogeneity of the power distribution of the HWS return beam, we could see a reduction of the cross-coupling between prismX and the spherical power. It was reduced by a factor 1.5 (with 120 udiopters/ 34 urad) compared to last night. We scheduled a ring heater test for tonight to confirm if the situation has improved.

Another important parameter is the sensor noise floor at high frequency (time scale of minutes). The noise on the sensor is higher than expected and this will limit our ability to see high spatial resolution changes. After today's work, the rms of the noise over 10 mins is reduced by a factor 3 (see figure 6).

We still need to test the impact of our system on the ALS beam and vice versa.

Images attached to this report
Comments related to this report
aidan.brooks@LIGO.ORG - 09:50, Tuesday 29 May 2018 (42186)

I've added the same wavefront plots with the colorscale extended to 450nm and the magnification corrected to 23.5 rather than 20.5. 

* We discovered a sign error in the wavefront reconstruction algorithm. Previous negative lens wavefronts were shown as positive lenses. This has been corrected here.

Images attached to this comment
marie.kasprzack@LIGO.ORG - 15:47, Friday 01 June 2018 (42291)TCS

The second test of the ring heater after the beam optimization mentioned above (night of May 25) confirms that the noise is reduced in the measurement. However there is still coupling with the prism_x/y, indicating that the beam was not centered on ETMY.

To estimate the coupling, the model (corrected for the magnification) was fitted with a linear combination of the measured spherical power and the tilts (see figure 1). The coupling coefficients are for 7.5 prism_x and -4 for prism_y. The cylindrical power isn't coupled with the spherical power. The corrected data is matching the model quite well once the ring heater is on, but there is still discrepancy between hour 24 and 30: there might be another mechanism driving the drift.

Images attached to this comment
Displaying report 1-1 of 1.