ALSX laser was turned on, PLL is locked

I went to EX, turned on the ALSX laser and locked PLL.

EX is still in laser safe.

I had to manually set the slow feedback offset to about negative 800MHz until the beat note appeared on the correct side (lower than PSL). This was relieved by increasing the temperature setpoint by 0.26 C (23.67 to 23.93).