With the most current DRMI alignment, we found it hard to close the OMC ASC loops and had to put a few offsets in the AS WFS DC Centering loops in order to keep the OMC suspension from railing.
Since the AS WFS weren't holding any particular reference, I took the time to offload the beam into the OMC using OM1 and OM2, of course this mis-centers the AS WFS so then I pico-ed the beam back onto AS_A and AS_B. This leaves about 80% margin on the OMC_SUS DACs. I then offloaded the control signals for the DC_Centering loops and the OMC_ASC to their respective alignment sliders.
Also, I realized the the OMC guardian state "ASC_QPD_ON" doesn't reflect the OM actuation sign flip so I changed that as well and committed to SVN.