marc.pirello@LIGO.ORG - posted 15:01, Friday 08 June 2018 (42406)
Timing Comparator ECR Complete

E. Merilh, M. Pirello

Today we completed the modification to the Timing Comparator chassis at X-END, the following work was completed on each chassis.

E1800008-v1 Replace 5V regulator with separate power supply.

E1200034-v6 & E1700246-v1  Add more frequency counters to unused Timing Comparators channels.

Previous Alog can be seen here ALOG40064

This completes the work on the timing comparators and closes:FRS4910  WP7383

 

 