Reports until 12:01, Tuesday 10 July 2018
H1 SUS (CDS)
jeffrey.kissel@LIGO.ORG - posted 12:01, Tuesday 10 July 2018 (42837)
Violin Mode Monitoring reverted to 10 banks in H1OAF
J. Kissel, J. Warner, D. Barker

While trying to add a few seismic channel BLRMS to the OAF model, we found that some ~2700 addition channels were also being added. This was a result of the update to the 
    /opt/rtcds/userapps/release/sus/common/models/DARMERR_VIOLIN_MODE_MONITOR_MASTER.mdl
that was rolled in during last week's update of the violin mode damping filters (see LHO aLOG 42752, IIET Ticket 8759, ECR E1700286). We don't yet want to perform this change to the OAF model, since it pushes the front-end code past its computational clock-cycle turn-around time limit. We'll look at re-installing once we've re-assessed the OAF model for splitting in half (see IIET Ticket 10520).

For now, I've reverted the library part to just before Stuart's upgrade 

jeffrey.kissel@zotws10:/opt/rtcds/userapps/release/sus/common/models$ svn up -r 17490 DARMERR_VIOLIN_MODE_MONITOR_MASTER.mdl
Updating 'DARMERR_VIOLIN_MODE_MONITOR_MASTER.mdl':
U    DARMERR_VIOLIN_MODE_MONITOR_MASTER.mdl
Updated to revision 17490.
jeffrey.kissel@zotws10:/opt/rtcds/userapps/release/sus/common/models$
such that Jim can push forward with his changes.