CDS Tuesday Maintenance Summary

WP7696 DMT OS upgrade

Greg:

All three production dmt machines were upgraded to SL7.5

WP7697 Add BRS and SENSCOR channels to DAQ GDS Broadcaster

Dave:

As per John Z's request, I added one BRS and two SENSCOR DQ channels to the DAQ GDS broadcaster

+[H1:ISI-GND_BRS_ETMY_RX_OUT_DQ]
+[H1:ISI-GND_SENSCOR_ETMX_SUPER_X_OUT_DQ]
+[H1:ISI-GND_SENSCOR_ETMY_SUPER_Y_OUT_DQ]


Matlab and h0epics move to new VM machine

Carlos, Ryan, Dave, Jeff B:

The virtual machines matlab and h0epics were moved to a new VM server. We started the IOCs which run on h0epics (dust monitors, weather stations, dewpoint monitors). Weather channel alarm levels were restored from autoburt.

WP7702 h1pemcs model changes

Robert, Philippe, Dave:

Several changes to h1pemcs:

Renamed six accelerometers

Added two ESD power monitor channels to the first two channels of the fourth ADC

Instead of acquiring the first 16 channels of the fourth ADC to DAQ, now acquire the last 16 channels (still at 2048Hz)

The fourteen channels following the ESD monitor channels are available as test-points (no longer in daq)

Please see separate alog for details

WP7703 Add oplev blrms channels to HLTS

Jeff K, Dave:

New h1susbs,pr3,sr3 models were installed.

WP7704 IPC SUSPOINT infrastructure ISI to SUS feed-forward controls of QUAD.

Jeff K, Dave:

Added IPC senders on h1isiitm[x,y] (one each) and h1isietm[x,y] (two each for ETM and TMS).  Added receives on SUS QUAD models.

QUAD SUS and ISI models were restarted.

WP7700 ISI HAM and BSC improved watchdog

Hugh, Dave:

New code for all HAM and BSC ISI models. All models were restarted.

WP7706 h1oaf addition of SUSPOINT DARM BLRMS

Jim W, Dave:

new h1oaf model was installed.

DAQ Restart

Dave:

DAQ was restarted at 13:07 PDT to support the above changes. h1nds1 did not restart cleanly and required a manual restart (via monit) at 13:30.

 