Reports until 17:19, Thursday 12 July 2018
H1 PSL
jason.oberling@LIGO.ORG - posted 17:19, Thursday 12 July 2018 (42878)
PSL Work Today

P. King, J. Oberling

Peter worked to recover the PMC, FSS, and ISS this morning.  For details, see his alog here.

After Peter was finished, I re-installed the MOPA lid and the FE power monitor pick-off; I then worked on aligning the pick-off, finishing in the afternoon.  The power out of the FE was measured using the roving 300W power meter to be 33.6W; I calibrated the pick-off to this value.  At this point I noticed something strange.  The output of the pick-off takes a long time (10s of minutes) to settle down and level off; the power reading on the power meter did not change during this "warm up" period.  I don't remember it doing this upon first installation, so this is something to keep an eye on.  After a lengthy warm-up period I checked the pick-off to make sure it wasn't getting hot (an indication of the pick-off being misaligned) and it was cool to the touch.  With the pick-off installed, a slight realignment into the 70W amp was required.  Most of the alignment was off in pitch, which holds together with the first time we installed this pick-off.  Upon realignment the output of the 70W amplifier was 75.8W; I re-calibrated the 70W power monitor PD to this value.

I then proceeded to reinstall the ISS AOM.  Using low power, I roughly aligned the AOM to the beam using the aperture in the AOM cover.  This done, I looked for a diffracted beam, but couldn't find one.  In addition, the beam on the AOM looks much larger than I remember it being.  Not wanting to damage anything when we're so close to having the beam back, I stopped here for the day.  So the only things left to do before the PSL is ready is to align the ISS AOM and close the ISS loop.  I left the FE and 70W amplifier OFF overnight.