Reports until 19:07, Friday 13 July 2018
H1 ISC
georgia.mansell@LIGO.ORG - posted 19:07, Friday 13 July 2018 (42901)
PRMI locked, build-up low, more alignment work to be done
Sheila, Georgia
 
This afternoon we locked PRMI, the buildups are still low, we are probably still clipping. Work in progress.
 
We returned the alignment sliders to the positions of the last DRMI on July 9 at 22:00:00 UTC, aligned PRY, MICH, then PRMI.
 
We had low power and bad initial alignment to start so I had to do some dodgey things to get PRMI locked: we paused the ISC_DRMI guardian, changed the MICH triggers in the LSC_TRIG_MTRX (upper threshold 3, note a trap for young players: these triggers are normalised to the power listed on the LSC overview screen), and increases the gain in the MICH2 and PRCL2 filter banks. 
 
We got PRMI buildups of ~15 on POPAIR_B_RF90_I_NORM and ~6 on POPAIR_B_RF90_I_NORM at 01:15:00 UTC July 14, aligning the BS, PRM and PR2.