Displaying report 1-1 of 1.
Reports until 10:50, Monday 16 July 2018
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 10:50, Monday 16 July 2018 (42916)
PSL Weekly Report (FAMIS #7499)

There is plans for ISS work tomorrow morning during Maintenance. 

We are laser HAZARD in the LVEA.

Laser Status:
SysStat is good
Front End Power is -0.003878W (should be around 30 W)
HPO Output Power is 0.2576W
Front End Watch is GREEN
HPO Watch is RED

PMC:
It has been locked 3 days, 2 hr 56 minutes (should be days/weeks)
Reflected power = 20.37Watts
Transmitted power = 48.31Watts
PowerSum = 68.68Watts.

FSS:
It has been locked for 0 days 3 hr and 25 min (should be days/weeks)
TPD[V] = 2.494V (min 0.9V)

ISS:
The diffracted power is around 2.0% (should be 3-5%)
Last saturation event was 0 days 0 hours and 0 minutes ago (should be days/weeks)

Possible Issues:
Front End Power is Low
PMC reflected power is high
ISS diffracted power is Low
LRA out of range, see SYSSTAT.adl

Displaying report 1-1 of 1.