green locking + alignment progress

Jenne, Sheila, Craig, Georgia, Keita

Both green arms are locking well now.  

The main problem we were having with the Y arm yesterday seems to have been that the second boost was not engaged.  Once this was engaged we could run the WFS, we added 50 dB of gain to DOF2 for the Yarm.  We were able to engage the slow feedback for both arms with no problems now that the suspension bug is fixed. The only thing we still need to do for the green arm alignment is set the camera offsets since the cameras have been moved. 

Craig got measurements of the ugfs and spectra for the X arm green locking which he will post. 