ISS coefficients
Attached are the old and new coefficients used to calculate the percentage of diffracted power.  Based on 65.6 W incident
on the pre-modecleaner.

    The old polynomial was 107.476x**2-83.072x+16.063.  The new polynomial is 129.252x**2-100.701x+19.7562.

    The change was accepted into SDF.
Images attached to this report