Displaying report 1-1 of 1.
Reports until 08:15, Monday 23 July 2018
H1 PSL
jim.warner@LIGO.ORG - posted 08:15, Monday 23 July 2018 (43013)
PSL Weekly


Laser Status:
SysStat is good
Front End Power is -0.006326W (should be around 30 W)
HPO Output Power is 0.2797W
Front End Watch is GREEN
HPO Watch is RED

PMC:
It has been locked 4 days, 0 hr 58 minutes (should be days/weeks)
Reflected power = 18.65Watts
Transmitted power = 46.11Watts
PowerSum = 64.75Watts.

FSS:
It has been locked for 0 days 9 hr and 11 min (should be days/weeks)
TPD[V] = 2.572V (min 0.9V)

ISS:
The diffracted power is around 0.41% (should be 3-5%)
Last saturation event was 4 days 0 hours and 46 minutes ago (should be days/weeks)

Possible Issues:
Front End Power is Low
PMC reflected power is high
ISS diffracted power is Low
LRA out of range, see SYSSTAT.adl
 

Displaying report 1-1 of 1.