Reports until 14:21, Tuesday 24 July 2018
H1 ISC
daniel.sigg@LIGO.ORG - posted 14:21, Tuesday 24 July 2018 - last comment - 13:33, Wednesday 25 July 2018(43041)
Swap ALS phase frequency discriminator (PFD)

Nolan Marc Dick Daniel

We swapped the ALS PFD with a unit that had its LO TNC/PCB/SMA/SMA/coax/SMA input arrangement replaced by a simple TNC/coax/SMA. Furthermore, the TNC connectors are no longer isolated. This should reduce any crosstalk inside the PFD between the 2 ALS VCOs.

While we were at the rack we noticed that some of the N bulkheads in the VCOs and FDDs were very loose. One of them rattled when we wiggled the cable. We tightened them all. We noticed that one of the cables between the VCO and the FDD had 2 ~5dB attenuator installed, whereas the other one had none. This was fixed as well. Both FDDs now have a proper 13dBm at the input.

Comments related to this report
marc.pirello@LIGO.ORG - 13:33, Wednesday 25 July 2018 (43070)

The modification is documented in this ALOG from LLO, with pictures!

https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=26227

The SN of the unmodified PFD we removed is S1000761.  The SN of the modified spare PFD we installed is S1000756.