SQZT6 SEED and LO Mode Matching

Yesterday, Sheila and I gathered the information on the measurements of seed mode (see 43084), and got the conclusion that the seed waist is 556um at 3m before the upper periscope mirror.

Then I measured the beam mode profile coming out from the LO fiber coupler, which is divergent with waist 188um at 1.12m before the fiber coupler (Beam fitting as attached.)

If the estimation from the measurements is good enough, a potential mode matching solution is shown as below (I hereby copied the layout and labels from LLO):

For future use, I attached the alm matlab code of the mode matching solutions that can reproduce the graphs. 

I will begin to install lenses and place them to rough positions without the seed beam.


I found that the Homodyne filters have already been added, including anti-whitening and calibration ones.

Images attached to this report