Displaying report 1-1 of 1.
Reports until 09:30, Tuesday 31 July 2018
H1 SUS (ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 09:30, Tuesday 31 July 2018 (43143)
Re-Balance of H1SUSITMY PUM/L2 Stage Actuators
J. Kissel
https://tinyurl.com/LIGOSUSActuatorTuning Table

I've balanced the ITMY PUM/L2 coils using the demodulated optical lever method (LHO aLOGs 11392 and 9453).

I'll characterize in more detail later, but here're the results:
      Former          New          % Difference
UL   +0.973282       +0.971803     +0.15196%
LL   -1.01098        -1.01146      -0.047479%
UR   -0.98898        -0.988465      0.052074%
LR   +1.02728        +1.02881      -0.14894%

The encouraging news is that the balance hasn't changed much on the one QUAD suspension we didn't change. These new balance values have been accepted into the SDF system.
Displaying report 1-1 of 1.