WP7753 h1ascimc model change, add fast channels to DAQ

Sheila, Dave:

A new h1ascimc model was started with a new DAQ configuration:

+: fast channel H1:ASC-AS_A_RF45_I_SUM_OUT_DQ added to the DAQ
+: fast channel H1:ASC-AS_A_RF45_Q_SUM_OUT_DQ added to the DAQ

the DAQ was restarted.

This reminded me of the RCG3.2.3 work I had done on h1pemmx some time ago. It was a test system for the RCG3.2.3 upgrade of the SUS-QUAD models. Both its models and its mx_stream had been upgraded to 3.2.3 to show that the DAQ error could be cleared if the new mx_stream is ran. After the DAQ was restarted it was left running 3.2.3 models and 3.2 mx_stream (like the SUS-QUADs are). I recompiled h1ioppemmx and h1pemmx using rcg3.2 and restarted them, clearing the DAQ error on these models.

Comments related to this report
georgia.mansell@LIGO.ORG - 14:23, Friday 03 August 2018 (43239)

While the PIT and YAW signals from the ASC WFS are normalised, the SUM is not. We have modified the channels for ASC_AS_A_RF45_I and Q SUM the to include power normalisation.